EPG has been productively licensed by ISO9002 Top quality Administration Method, ISO9001 Top quality Administration Method, API certificate, ISO/TS16949:2002 and ISO10012 measurement administration program. we provide 1-end remedy for the obtain of mechanical energy transmission items in China. If you require any data or samples, make sure you speak to us and you will have our before long reply.
313kVA (250kw) Super Silent EPTT Generator with CE Approved (GDC313*S)
GODLIKE EPTT sort gensets
uuml GODLIKE EPTT provides a wiEPTTrange of gensets, as properly as other sorts of EPT
EPT and services.
uuml Gensets: One-stage and 3-period turbines, manually operated or with
EPTT (AMF) procedure, stationary or cell, put in outdoor – with
Soundproof canopy, or indoors – open body types, masking a EPTT range
In between 10 and 2000kVA.
uuml The GODLIKE EPTT genset series has been developed to fulfill all the energetic
Requirements of every variety of electrical EPT, obtaining a compact layout, EPTTful,
Dependable, effortless to use and with silent procedure.
uuml GODLIKE EPTT gensets are equipped with diesel engines from popular genset engines makers.
Inner combustion motor – Godlike EPTT gensets are equipped with
EPTT top quality, planet broad popular engines.
The engines equipping the JDG collection are dependable, reduced-noise,
EPTTful, with lower gasoline use and made employing revolutionary
EPTnologies.
four stroke, water-cooled, direct EPT, in-line 2-6 cylinders, naturally aspirated or turbocharged EPTT engines.
EPT or digital governor.
JCEP starter motor twelve/24V DC.
Battery charging alternator 12/24V DC.
Fuel pump and fuel filter(s), oil pump and oil filter(s), gasoline EPT
EPT, air filter(s).
Oil strain sensors, engine temperature sensors.
EPTT motor shutdown in scenario of genset malfunction.
Pre-heating method (only for automatic gensets).
Exhaust technique with minimal-noise muffler(s) and EPTow(s).
GENERATOR – EPT, 4 pole, solitary bearing or double bearing, brushless.
Self enthusiastic and self controlled by AVR (EPTT Voltage Regulator).
IP23 defense diploma.
Insulation class H.
SKID (Base Body)
The engine-generator assembly is made by coupling the two key
Components by means of the SAE coupling program. Many thanks to the EPTT anti-
Vibration rubber damper pads, the genset does not induce apparent
Vibrations to the bordering basis. The maXiHu (West EPT) Dis.mum vibration stage
Induced to the genset base frame is 5mm/s.
Gasoline TANK, is integrated in the genset’s base body. As genset
EPT, GODLIKE EPTT can adapt to the customers’ requests by enlarging
Or decreasing the fuel tank capacity, in orEPTTto make certain the asked for genset
JCEPnomy. In addition, the gensets can be outfitted with huge capability
AuXiHu (West EPT) Dis.liary (exterior) gasoline tanks with automated refueling system.
SOUNDPROOF Cover, made from electrostatic spray-
Painted metal sheet, which minimizes the corrosive action of atmospheric
And surrounding environmental brokers.
EXEPTUST MUFFLER, guarantees silent genset procedure and
Minimizes the environmental affect of exhaust fuel according to the
Appropriate EU stXiHu (West EPT) Dis.Hu (West EPT) Dis.rds.
COMMAND AND Handle PANEL
The management panel is incEPTTd in the genset assembly, fitted on the
Genset’s base body and can be visualized via a single of the canopy
Door’s pleXiHu (West EPT) Dis.glas window.
The gensets are outfitted with manually operated or automated
Operation electric powered panels, in accordance to the customer’s ask for.
The panels provide multiple set-up and defense features and operating
Modes. The gensets can also be remote operated and monitored making use of
The Computer, incXiHu (West EPT) Dis.Hu (West EPT) Dis. by means of Internet and GEPT, as an optional added. The
EPTT panel is welcoming and simple to use. The automatic control panels
Can be manufactures as a twin EPT board (the management-aspect
Equipment is separated from the switchEPT).
Top quality STHangEPTRDS
The GODLIKE EPTT series gensets are created and made by our
EPTT according with the latest issued CE!
| Product No |
Genset Product | EPTT Out Place 400V/50HZ/1500RPM/3P/.8 ( Y ) |
EPTT Engine Product |
Stamford Alternator Product |
|
| EPT 40 degree | |||||
| one | GDC43 | 34KW | 43KVA | 4BT3.9G1/36KW | UCI224C |
| 2 | GDC43 | 34KW | 43KVA | 4BT3.9G2/36KW | UCI224C |
| 3 | GDC50 | 40KW | 50KVA | 4BTA3.9G2/50KW | UCI224D |
| four | GDC60 | 48KW | 60KVA | 4BTA3.9G2/50KW | UCI224E |
| five | GDC100 | 80KW | 100KVA | 6BT5.9G1/92KW | UCI274C |
| six | GDC100 | 80KW | 100KVA | 6BT5.9G2/92KW | UCI274C |
| 7 | GDC120 | 96KW | 120KVA | 6BTA5.9G2/106KW | UCI274D |
| eight | GDC135 | 108KW | 135KVA | 6BTAA5.9G2 /120KW | UCI274E |
| nine | GDC160 | 128KW | 160KVA | 6CTA8.3G2/163KW | UCI274F |
| 10 | GDC180 | 144KW | 180KVA | 6CTA8.3G2/163KW | UCI274G |
| 11 | GDC200 | 160KW | 200KVA | 6CTAA8.3G2/183KW | UCI274H |
| 12 | GDC225 | 180KW | 225KVA | 6LTAA8.9G2/220KW | UCI274J |
| 13 | GDC250 | 200KW | 250KVA | 6LTAA8.9G2/220KW | UCI274K |
| 14 | GDC250 | 200KW | 250KVA | NT855-GA/231KW | UCI274K |
| 15 | GDC250 | 200KW | 250KVA | MTA11-G2A/234KW | UCI274K |
| 16 | GDC300 | 240KW | 300KVA | NTA855-G1A /261KW | HCI444D |
| 17 | GDC300 | 240KW | 300KVA | NTA855-G1B/284KW | HCI444D |
| 18 | GDC313 | 250KW | 313KVA | NTA855-G1B/284KW | HCI444ES |
| 19 | GDC313 | 250KW | 313KVA | MTAA11-G3 /282KW | HCI444ES |
| 20 | GDC325 | 260KW | 325KVA | NTA855-G1B/284KW | HCI444ES |
| 21 | GDC350 | 280KW | 350KVA | NTA855-G2A/313KW | HCI444E |
| 22 | GDC350 | 280KW | 350KVA | NTA855-G4/317KW | HCI444E |
| 23 | GDC375 | 300KW | 375KVA | NTAA855-G7/343KW | HCI444FS |
| 24 | GDC375 | 300KW | 375KVA | KTA19-G2 /336KW | HCI444FS |
| twenty five | GDC400 | 320KW | 400KVA | NTAA855-G7A/407KW | HCI444F |
| 26 | GDC450 | 360KW | 450KVA | KTA19-G3/403KW | HCI544C |
| 27 | GDC500 | 400KW | 500KVA | KTA19-G3A/448KW | HCI544C |
| 28 | GDC500 | 400KW | 500KVA | KTA19-G4 /448KW | HCI544C |
| 29 | GDC550 | 440KW | 550KVA | KTAA19-G5 /470KW | HCI544D |
| 30 | GDC600 | 480KW | 600KVA | KTAA19-G6/520KW | HCI544E |
| 31 | GDC600 | 480KW | 600KVA | KTA19-G8/575KW | HCI544E |
| 32 | GDC625 | 500KW | 625KVA | KTAA19-G6A /610KW | HCI544FS |
| 33 | GDC625 | 500KW | 625KVA | KT38-G/560KW | HCI544FS |
| 34 | GDC750 | 600KW | 750KVA | KTA38-G2/664KW | LVI634B |
| 35 | GDC800 | 640KW | 800KVA | KTA38-G2B/711KW | LVI634C |
| 36 | GDC900 | 720KW | 900KVA | KTA38-G2A/813KW | LVI634D |
| 37 | GDC1000 | 800KW | 1000KVA | KTA38-G5/880KW | LVI634E |
| 38 | GDC1125 | 900KW | 1125KVA | KTA38-G9/1089KW | LVI634F |
| 39 | GDC1250 | 1000KW | 1250KVA | KTA50-G3/1097KW | LVI634G |
| forty | GDC1375 | 1100KW | 1375KVA | KTA50-G8/1200KW | PI734B |
| forty one | GDC1500 | 1200KW | 1500KVA | KTA50-GS8/1287KW | PI734C |
| Merchandise No |
Genset Product | EPTT Out Place 400V/50HZ/1500RPM/3P/.eight ( Y ) |
EPTT Motor مدل |
Godlike Alternator Product |
|
| EPT 40degree | |||||
| one | GDC23 | 18KW | 23KVA | 4B3.9G1/24KW | JDG 184E |
| two | GDC23 | 18KW | 23KVA | 4B3.9G2/24KW | JDG 184E |
| 3 | GDC28 | 22KW | 28KVA | 4B3.9G1/24KW | JDG 184F |
| four | GDC28 | 22KW | 28KVA | 4B3.9G2/24KW | JDG 184F |
| five | GDC31 | 25KW | 31KVA | 4BT3.9G1/36KW | JDG 184G |
| 6 | GDC31 | 25KW | 31KVA | 4BT3.9G2/36KW | JDG 184G |
| 7 | GDC40 | 32KW | 40KVA | 4BT3.9G1/36KW | JDG224C |
| 8 | GDC40 | 32KW | 40KVA | 4BT3.9G2/36KW | JDG 224C |
| nine | GDC50 | 40KW | 50KVA | 4BTA3.9G2/50KW | JDG 224D |
| ten | GDC56 | 45KW | 56KVA | 4BTA3.9G2/50KW | JDG 224ES |
| eleven | GDC60 | 48KW | 60KVA | 4BTA3.9G2/50KW | JDG 224E |
| 12 | GDC100 | 80KW | 100KVA | 6BT5.9G1/92KW | JDG 274C |
| 13 | GDC100 | 80KW | 100KVA | 6BT5.9G2/90KW | JDG 274C |
| 14 | GDC120 | 96KW | 120KVA | 6BTA5.9G2/106KW | JDG 274DS |
| 15 | GDC135 | 108KW | 135KVA | 6BTAA5.9G2 /120KW | JDG 274ES |
| 16 | GDC160 | 128KW | 160KVA | 6CTA8.3G2/163KW | JDG 274F |
| 17 | GDC180 | 144KW | 180KVA | 6CTA8.3G2/163KW | JDG 274G |
| 18 | GDC200 | 160KW | 200KVA | 6CTAA8.3G2/183KW | JDG 274H |
| 19 | GDC225 | 180KW | 225KVA | 6LTAA8.9G2/220KW | JDG 274J |
| 20 | GDC250 | 200KW | 250KVA | 6LTAA8.9G2/220KW | JDG 274K |
| 21 | GDC250 | 200KW | 250KVA | NT855-GA/231KW | JDG274K |
| 22 | GDC250 | 200KW | 250KVA | MTA11-G2A/234KW | JDG274K |
| 23 | GDC275 | 220KW | 275KVA | NTA855-G1A/261KW | JDG 314DS |
| 24 | GDC300 | 240KW | 300KVA | NTA855-G1A/261KW | JDG 314D |
| twenty five | GDC313 | 250KW | 313KVA | NTA855-G1B/284KW | JDG 314ESS |
| 26 | GDC313 | 250KW | 313KVA | NTA855-G1B/284KW | JDG 314ESS |
| 27 | GDC313 | 250KW | 313KVA | MTAA11-G3 /282KW | JDG 314ESS |
| 28 | GDC325 | 260KW | 325KVA | NTA855-G1B/284KW | JDG 314ES |
| 29 | GDC350 | 280KW | 350KVA | NTA855-G2A/313KW | JDG 314E |
| thirty | GDC350 | 280KW | 350KVA | NTA855-G4/317KW | JDG 314E |
| 31 | GDC375 | 300KW | 375KVA | NTAA855-G7/343KW | JDG 314FS |
| 32 | GDC375 | 300KW | 375KVA | KTA19-G2 /336KW | JDG 314FS |
| 33 | GDC400 | 320KW | 400KVA | NTAA855-G7A/407KW | JDG 314F |
| 34 | GDC450 | 360KW | 450KVA | KTA19-G3 /403KW | JDG 354C |
| 35 | GDC500 | 400KW | 500KVA | KTA19-G3A/448KW | JDG 354D |
| 36 | GDC500 | 400KW | 500KVA | KTA19-G4 /448KW | JDG 354D |
| 37 | GDC550 | 440KW | 550KVA | KTAA19-G5 /470KW | JDG 354ES |
| 38 | GDC575 | 460KW | 575KVA | KTAA19-G6/520KW | JDG 354E |
| 39 | GDC600 | 480KW | 600KVA | KTA19-G8/575KW | JDG 354E |
| forty | GDC625 | 500KW | 625KVA | KTAA19-G6A /610KW | JDG 354FS |
| forty one | GDC625 | 500KW | 625KVA | KT38-G/560KW | JDG 354FS |
| forty two | GDC725 | 580KW | 725KVA | KT38-GA/711KW | JDG 354G |
| 43 | GDC750 | 600KW | 750KVA | KTA38-G2/664KW | JDG 404B |
| forty four | GDC800 | 640KW | 800KVA | KTA38-G2B/711KW | JDG 404C |
| forty five | GDC900 | 720KW | 900KVA | KTA38-G2A/813KW | JDG 404D |
| forty six | GDC1000 | 800KW | 1000KVA | KTA38-G5/880KW | JDG 404E |
| 47 | GDC1125 | 900KW | 1125KVA | KTA38-G9/1089KW | JDG 404F |
| 48 | GDC1250 | 1000KW | 1250KVA | KTA50-G3/1097KW | JDG 404G |